ABB LDMUI-01 综合保护电源接口模块的相关信息可以总结如下:
ABB LMUI-01 Integrated protection power interface module information can be summarized as follows:
Basic features:
Function: This module allows groups of users to be assigned on project stations (local stations) to target stations in the project tree, where target stations refer to all operator stations in the project.
User group management: User groups can be managed by adding, deleting, and editing, and the user group assigned to the target site in the project tree needs to be provided to the user group of each operator site.
Display allocation: In Freelancer projects, graphical displays in the Common Display Pool (CDP) can be assigned to each operational resource and downloaded to the appropriate operational station.
Technical specifications (according to the information in reference article 1) :
CPU Processor: Supports Intel Atom E620T, E640T, E660T, and E680T.
Memory: Up to 1GB DDR2 on-board, single 32-bit channel memory.
Graphics card: Integrated Intel GMA 600 graphics card, supporting 1280x768 LVDS and 1280x1024 SDVO dual independent display interface.
Network: 1 gigabit Ethernet LAN controller.
Storage: Provides 32GB on-board SSD storage device (optional other capacity such as 2GB/4GB/8GB/16GB).
Ports: 7 USB 2.0 hosts, 1 USB 2.0 host/client (optional), 3 PCIe x1, 1 CAN bus, 1 ExpressCard (PCIe signal only), 8-bit DIO port, SDIO/MMC port (Type 6).
Operating temperature: -40°C to 85°C, wide temperature support.
Application scenario:
Thanks to its wide temperature support and stable version control platform, the ABB LDMUI-01 Integrated Protection Power interface module is ideal for use in a variety of environments, especially in applications requiring industrial control automation.
Additional information:
In freelancer operations, the operator station (if lite OS) supports up to 5 FGRS (graphical resources), including FGRS under the Lite OS node.
User actions are recorded in the signal sequence log for tracking and auditing purposes.