ABB REF630 馈线保护继电器的安装和配置需要注意以下几个要点:
检查产品完整性:在安装前应检查REF630装置是否完整,包括所有配件和文档 。
阅读手册:在安装和配置前,应详细阅读REF630的用户手册,了解其功能、特性和具体操作步骤 。
环境要求:确保安装环境符合ABB REF630的技术规格要求,包括温度、湿度等环境因素 。
电源配置:根据REF630的电源要求进行配置,确保电源的稳定性和可靠性 。
通信设置:由于REF630支持IEC61850通信标准以及DNP3和IEC 60870-5-103通信协议,需要正确设置通信参数以确保与变电站和SCADA系统的无缝连接 。
配置保护功能:根据具体的应用需求配置REF630的保护功能,包括过流保护、接地故障保护等,并设置相应的定值 。
HMI配置:REF630配备有大尺寸且可分离的HMI(人机界面),需要根据操作习惯和需求进行配置 。
测试和验证:在安装和配置完成后,应进行充分的测试和验证,确保REF630的所有功能正常工作,并且保护动作准确无误 。
遵守安全规范:在整个安装和配置过程中,应遵守相关的安全规范和操作程序,确保人员和设备的安全。
全寿命周期服务:ABB提供广泛的产品全寿命周期服务,确保REF630的长期稳定运行和维护 。
The REF630 is a feeder protection and measurement device in the ABB Relion product family, a member of the 630 Protection Measurement and control device product family. Known for its functional scalability and flexible configuration, the device is suitable for use as primary protection for overhead lines and cable feeders in neutral neutral, resistance grounded, compensated or directly grounded distribution networks.
The REF630 design is available in four preconfigurations to meet typical feeder protection and control requirements, and can accommodate open/closed loop feeder applications, radiant overhead/hybrid line feeder applications, ring/mesh feeder applications, and segmented busbars. In addition, preconfiguration can easily meet the needs of specific applications with freely optional functionalities.
The device has two configurations: single bus and double bus, and each bus configuration has one or two circuit breakers and multiple switching device configurations. The REF630 also supports a large number of manual and electric disconnecting switches and ground switches, so it can be used to control many types of switchgear 186.
In terms of communication, the REF630 fully supports the substation IEC61850 communication standard, covering both vertical and horizontal communication, including GOOSE messages with switching signals and analog signals. In addition, the REF630 supports DNP3 (TCP/IP) and IEC 60870-5-103 (serial port) communication protocols, providing seamless connectivity to various substations and SCADA systems.
Key features of the REF630 also include a wide range of protection and measurement and control functions, a combination of highly sensitive and selective multi-frequency admittance ground protection, advanced and fast short-circuit, ground fault location functions, 8 RTD/mA input and 4 mA output, support for IEC61850 1st and 2nd editions, including GOOSE, It also supports Modbus, DNP3, IEC 60870-5-103 communication protocol 186.
ABB REF630 feeder protection relays need to be installed and configured in the following ways:
Check product integrity: The REF630 unit should be checked for integrity before installation, including all fittings and documentation.
Read the manual: Before installing and configuring the REF630, read the REF630's user manual to understand its functions, features, and procedures.
Environment requirements: Ensure that the installation environment complies with ABB REF630 specifications, including temperature, humidity and other environmental factors.
Power configuration: Configure according to the REF630 power requirements to ensure power stability and reliability.
Communication Settings: Since the REF630 supports the IEC61850 communication standard and the DNP3 and IEC 60870-5-103 communication protocols, the communication parameters need to be set correctly to ensure seamless connection to the substation and SCADA systems.
Configure the protection function: Configure the protection function of the REF630 according to the specific application requirements, including overcurrent protection and ground fault protection, and set the corresponding value.
HMI configuration: The REF630 is equipped with a large and detachable HMI (Human Machine Interface) that needs to be configured according to operating habits and requirements.
Testing and verification: After installation and configuration, adequate testing and verification should be carried out to ensure that all functions of the REF630 are working properly and that protection actions are correct.
Comply with safety regulations: During the entire installation and configuration process, comply with relevant safety regulations and operating procedures to ensure the safety of personnel and equipment.
Full Life Cycle Service: ABB offers a wide range of product full life cycle services to ensure long-term stable operation and maintenance of the REF630.
GE | IC693NIU004 |
A-B | 80025-523-09-R |
A-B | 81001-408-52-R |
NI | PXI-4130 |
AMAT | 0150-05210 |
A-B | 1766-L32BWAA |
MESTO | A413240 |
EPRO | PR9376/010-011 |
EMERSON | VEGAWAVE61 |
HIMA | F6217 |
HIMA | Z7128 |
ABB | 3BSE018162R1 PM864A |
MTL | MTL 5573 |
MTL | MTL 5541 |
MTL | MTL 5546Y |
Fireye | EB700 |
Fireye | EUV |
Fireye | EP260 |
Fireye | ED510 |
Deltav | VE4014 |
Deltav | VE4001S2T2B4 |
HIMA | K9203 |
HIMA | Z7127/6217 |
HIMA | F3236 |
ABB | CI920AS |
HIMA | VR-H4135 |
ABB | FAU810 |
Foxboro | E69F-BI2 |
WATLOW ANAFAZE | 997D-11CC-JURG |
UE | LDP1WC/250P-16 |
Vibrating | VEGAWAVE61 |
EPRO | PR9376/010-011 |
HIMA | H7506 |
TERASAKI | ERC 244 |
TERASAKI | ERC 233 |
TERASAKI | ERC 232 |
A-B | 1769-PA4 |
A-B | 1747-L542 |
A-B | 1769-OF4CI |
A-B | 1769-IF16C |
ABB | 57160001-K DSDO110 |
ABB | 57120001-P DSAI130 |
18030183032